Raised Floor Systems
Our many years of experience in the field of raised floors in data centers is the basis for a concept that is perfectly tailored to you. Suitability for everyday use and sustainability are particularly important to us, so that you can look to the future with peace of mind. We advise, plan and build the right raised floor for you - carefree and above all effective.

Maximizing Space and Datacenter Efficiencies
Installing a raised floor has many advantages. In addition to the fact that you can lay pipes and cables in this way, it is also ideal for air conditioning. In data center construction, for example, the raised floor is often used to direct the cold air precisely to where it is needed.
Raised floors in data centers are also a challenge. Incorrect design and configuration can lead to operational problems. Raised floors that are too small limit the assembly of IT components (point load too low). Oversized raised floors are expensive and difficult to maintain. In addition to these factors, conductivity and integration into the potential equalization play a decisive role in order to achieve a room shielding effect. Our many years of experience will help you to select, plan and install the right raised floor system for your company. Suitability for everyday use and sustainability are the focus of our concepts.
Data centre raised floors: more than a service void
Loads and structural capacity
Rack weight, concentrated loads and transport routes determine the design. Panels, pedestals and substructure must be considered as a system. Heavy batteries or new high-density racks need assessment before installation.
Airflow and openings
Where the floor is used as an air plenum, free cross-sections and perforated panels affect rack supply. Unsealed cable openings can bypass IT loads. Air distribution is coordinated with containment and cooling.
Services and accessibility
Cable routes, services and any leak detection require sufficient space and maintainable access. Fire protection, bonding and suitable surface properties are considered. A raised floor is not essential for every cooling or building concept.
Existing systems and expansion
Expansion allowances cover height, occupancy and structural capacity. Openings and modifications must be documented. Changes during live operation require assessment of airflow, access and neighbouring IT systems.
Advantage of High Knowledge
With high knowledge as a professional system supplier with more than 20 years of experience in design, installation and maintenance, you will find the optimal solution for your specific needs. Feel free to contact us for a consultation.
Advantage of High Knowledge
High Knowledge experts know the latest trends and developments in the industry. We have been successfully planning and implementing data centers of all sizes for over 20 years. With us you get the professional advice you need to be able to operate your data center safely and reliably. Feel free to contact us for a consultation.